SiPass Integrated Signal Modules

AFI5100 Input point module including base plate

AFI5100The AFI5100 is a programmable input controller used as part of a SiPass integrated system. It provides a local interface between the advanced central controller (AC5100‚ AC5102 or AC5200) and the devices used to monitor a facility‚ such as infrared detectors. When an input device that is connected to an AFI5100 changes status‚ the AFI5100 registers the status change and forwards this data to the controller. After checking the validity of the data‚ the controller sends the message to the SiPass integrated server‚ so the alarm-handling mechanism can respond appropriately.

Spec Sheet

Technical data
Interface To controller: RS485
Operating voltage 12 VDC ±10% or 24 VDC ±10%
Power consumption 50 W
Inputs 32 x internally supplied (supervised or unsupervised)
1 x Tamper (internally supplied)
1 x Fire override (potential-free or internally supplied)
Outputs 4 x Auxiliary relays (30 VDC‚ 2 A)
1 x Alarm output (open-collector 12VDC‚ 200 mA)
1 x Fire override relay (30 VDC‚ 2 A)
Firmware Flash upgradeable
Indicators Power‚ Activity‚ Communication Inputs‚ Output Peripheral supplies Fire override
Operating temperature 0 to +50 °C
Dimensions (W x H x D) 250 x 287 x 30 mm
Approval CE‚ UL294‚ C-Tick
Weight 1.35 kg

 

AFO5100 Output point module (16/16) including base plate

AFO5100The AFO5100 is an advanced‚ multi-purpose module that provides an interface between powered field-level input contact devices (such as elevator buttons) and output devices (such as override mechanisms) to the advanced central controller (AC5100‚ AC5102 or AC5200). It is designed for use in elevators that are integrated within an access control environment. A single AFO5100 can provide access control for up to 16 floors and multiple AFO5100 modules can be combined in an elevator system to provide access control for all floors. The fire override mechanism allows floors to be made automatically accessible during an emergency situation‚ a critical feature for sites where legislation requires strict emergency responses.

Spec Sheet

Technical data
Interface To controller: RS485
Operating voltage 12 VDC ±10% or 24 VDC ±10%
Power consumption 50 W
Inputs 16 x Isolated (unsupervised external voltage required)
1 x Tamper (internally supplied)
2 x Fire override (potential-free or internally supplied)
Outputs 16 x Relays (30 VDC‚ 2 A)
1 x Tamper (open-collector 12 VDC‚ 100 mA)
2 x Fire override relays (30 VDC‚ 2 A)
Firmware Flash upgradeable
Indicators Power‚ Activity‚ Communication Inputs‚ Output Peripheral supplies Fire override
Operating temperature 0 to +50 °C
Dimensions (W x H x D) 216 x 267 x 30 mm
Approval CE‚ UL294‚ C-Tick
Weight 1.3 kg

 

AFO5200 Output point module (8/8) including base plate

AFO5200The AFO5200 is an advanced‚ multi-purpose module that provides an interface between field-level input devices (such as passive infrared detectors) and output devices (such as locking devices) to the advanced central controller (AC5100‚ AC5102 or AC5200).

 

Technical data
Interface To controller: RS485
Operating voltage 12 VDC ±10% or 24 VDC ±10%
Current consumption Max. 2 A at 12 V, max. 1.5 A at 24 V
Inputs 8 x Isolated (internally supplied, unsupervised or supervised)
1 x Local input
1 x Fire override (potential-free or internally supplied)
Outputs 8 x Relays (30 VDC, 2 A)
1 x Local output (open-collector 9.7-12 VDC, 100 mA)
1 x Fire override relays (30 VDC, 2 A)
Firmware Flash upgradeable
Indicators Power, Activity, Communication Inputs, Output Peripheral supplies Fire override
Operating temperature 0 to +50 °C (32 to 122 °F)
Dimensions (W x H x D) 250 x 210 x 40 mm
Approval CE, UL294, C-Tick
Weight 1 kg