Single Reader Interfaces
Single Reader Interfaces provide a Clock&Data/Wiegand interface between a card reader and the advanced central controller (AC5102 or AC5200) for one card reader. When a cardholder presents an access card at an entry or exit reader the reader interface interprets the encoded information and sends this data to the controller. The controller then checks the validity of the cardholder‚ and if the appropriate permissions have been assigned‚ the controller sends a message back to the reader interface allowing it to unlock the door and provide passage. It can also report the status of the door (locked or unlocked) at any time.
Note: Single Reader Interfaces do not have an RS485 interface for card readers. They support Clock&Data or Wiegand readers only.
ADS5200 Single reader interface module including base plate
ADS5210 Single reader interface module including base plate and plastic housing
Single Reader Interface Spec Sheet
Technical data
Interface | FLN connection to controller: RS485 To readers:Clock&Data or Wiegand port |
Operating voltage | 12 VDC ±20 % |
Power consumption | 12 W |
Outputs | 1 x Lock output relay (30 VDC‚ 2 A) 1x Open-collector output (100 mA‚ 12 VDC) |
Inputs | 1 x REX-button 1 x Door contact 2 x Auxiliary All inputs unsupervised or supervised |
Tamper switch | Optional‚ auxiliary input |
Firmware | Flash upgradeable |
Indicators | Power‚ Activity‚ Communication |
Dimensions (W x H x D) | ADD5200: 125 x 125 x 34 mm ADD5210: 150 x 150 x 76 mm |
Weight | ADD5200: 0.25 kg ADD5210: 0.55 kg |
Approval | CE‚ UL294‚ C-Tick |
Dual Reader Interfaces
Dual Reader Interfaces provide an interface between a card reader and the advanced central controller (AC5102 or AC5200) for up to two card readers. When a cardholder presents an access card at an entry or exit reader the dual reader interface interprets the encoded information and sends this data to the controller. The controller then checks the validity of the cardholder‚ and if the appropriate permissions have been assigned‚ the controller sends a message back to the reader interface allowing it to unlock the door and provide passage. It can also report the status of the door (locked or unlocked) at any time.
ADD5100 Dual reader interface
ADD5110 Dual reader interface including base plate and plastic housing
ADD5160 Dual reader interface module in weatherproof housing
ADD5190 Dual reader interface module in cabinet
Dual Reader Interface Spec Sheet
Technical data
Interface | FLN connection to controller: RS485 To readers: One RS485 bus for up to two RS485 readers CerPass protocol) OR two Wiegand/Clock&Data ports |
Operating voltage | 24 VDC ±20 % |
Power output | Reader: 300 mA Ancillary: 1 A |
Power consumption | 25 W |
Outputs | 1 x Lock output relay (30 VDC‚ 2 A) 1 x Auxiliary relay (30 VDC‚ 2 A) |
Inputs | 1 x REX-button 1 x Door contact 3 x Auxiliary All inputs unsupervised or supervised |
Tamper switch | Optional‚ auxiliary input |
Firmware | Flash upgradeable |
Indicators | Power‚ Activity‚ Communication |
Dimensions (W x H x D) | ADD5100: 125 125 x 3 4mm ADD5110: 150 x 150 x 76 mm ADD5160: 189 x 180 x 60 mm ADD5190: 200 x 300 x 95 mm |
Weight | ADD5100: 0.3 kg ADD5110: 0.55 kg ADD5160: 0.5 kg ADD5190: 2.8 kg |
Approval | CE‚ UL294‚ C-Tick |
Eight Reader Interface
ADE5300 Eight-reader interface, including base plate
The ADE5300 provides a local interface between the advanced central controller (AC5100‚ AC5102 or AC5200) and up to 8 card readers. From the ADE5300‚ the information held within the access cards is transmitted to the controller. Each time an access attempt is made the controller verifies the data on the ID card and will then either allow or deny access. The ADE5300 can be configured to control up to 8 doors separately or up to 4 doors that include both entry and exit readers. All variations are possible; for example‚ you can have six single-reader doors and 1 dual-reader door connected to one ADE5300.
Technical data
Interface | FLN connection to controller: RS485 To readers: Support for eight readers via RS485 or Wiegand |
Operating voltage | 12 VDC ±10 % or 24 VDC -± 10 % |
Power output | Reader: 8 x 400 mA‚ 12 VDC Ancillary: 1 x 1.5 A‚ 12 VDC |
Current consumption | Max. 2 A at 12 V, max. 1.5 A at 24 V |
Outputs | 8 x Lock output relay (30 VDC, 2 A) 8 x Open-collector output (100 mA, 9.7-12 VDC) 2 x Fire override relay (30 VDC, 2 A) |
Inputs | 8 x Door contact 8 x Request-to-exit 16 x Auxiliary All inputs unsupervised or supervised 2 x Fire override (normal or enhanced mode) |
Tamper switch | Optional, auxiliary input |
Firmware | Flash upgradeable |
Indicators | Power, Activity, FLN Communication, Reader bus communication, Input/output, Fire override |
Dimensions (W x H x D) | 250 x 287 x 50 mm |
Weight | 1.65 kg |
Approval | CE, UL294, C-Tick |